FANOX/SEL/SHALLCO/COM保護電驛(Protection Relay)
3
FANOX 保護電驛4
http://www.yongyea.com.tw/ 永岳機電科技有限公司

FANOX SIL-C 十相保護電驛

SIL-C 

FUNCTIONS:

50 + SOTF + 50G + 50N + (4) 67/51 + (2) 67G/51G + (2) 67N/51N + 67GI
+ 67NI + 64REF + 46 + 46BC + 49 + 49T + 37 + (2) 27+ 27V1 + (2) 59 + (2)
59N/G + 47 + (4) 32 + (4) 81U/O + (4) 81R + 78 + (2) 24 + 79 + 74TCS +
60CTS + 60VTS + 50BF + SHB + CLP + 52 + 86 + HLT

COMMUNICATIONS:
A: USB (Modbus RTU) + RS485: (Modbus RTU, IEC60870-5-103 or DNP3.0
Serial)
B: USB (Modbus RTU) + RS485 (Modbus RTU, IEC60870-5-103 or DNP3.0
Serial) + RJ45 (Modbus TCP or DNP3.0 TCP or IEC60870-5-104)) + Web
Server + SNTP Protocol + IRIG-B
Attached: Feature comparison table - Fanox - Protection Relays.pdf

FANOX SIA-C 可前抽出式CO+LCO保護電驛

SIA-C 可前抽出式CO+LCO保護電驛


ˊ

FANOX SIL-G 主盤/發電機保護電驛

Protection Functions :
50(2) + SOTF + 50G + 50N +67(4) + 67G(2) + 67N(2) + 46 + 46BC + 49 + 37 +27(2) + 27V1 + 59(2) +59N/G(2) + 47 + 32(4) + 81U/O(4) + 81R(4) + 78 + 24(2) + 79 + 74TCS+ 60CTS + 60VTS + 50BF + SHB + CLP + 52 + 86

COMMUNICATIONS
A: USB (Modbus RTU) + RS485: (Modbus RTU, IEC60870-5-103 or
DNP3.0 Serial)
B: USB (Modbus RTU) + RS485 (Modbus RTU, IEC60870-5-103 or
DNP3.0 Serial) + RJ45 (Modbus TCP or DNP3.0 TCP) + IRIG-B
C: USB (Modbus RTU) + Ethernet - RJ45 (IEC 61850) + RJ45 (Modbus
TCP or DNP3.0 TCP) + IRIG-B
D: USB (Modbus RTU) + HSR – FO (IEC 61850) + RJ45 (Modbus TCP
or DNP3.0 TCP) + IRIG-B
E: USB (Modbus RTU) + PRP – FO (IEC 61850) + RJ45 (Modbus TCP
or DNP3.0 TCP) + IRIG-B
F: USB (Modbus RTU) + WiFi + RS485 (Modbus RTU, IEC60870-5-
103 or DNP3.0 Serial)
G: USB (Modbus RTU) + WiFi + RS485 (Modbus RTU, IEC60870-5-
103 or DNP3.0 Serial) + RJ45 (Modbus TCP or DNP3.0 TCP) + IRIG-B
H: USB (Modbus RTU) + WiFi + Ethernet - RJ45 (IEC 61850) + RJ45
(Modbus TCP or DNP3.0 TCP) + IRIG-B
I: USB (Modbus RTU) + WiFi + HSR – FO (IEC 61850) + RJ45 (Modbus
TCP or DNP3.0 TCP) + IRIG-B
J: USB (Modbus RTU) + WiFi + PRP – FO (IEC61850) + RJ45 (Modbus
TCP or DNP3.0 TCP) + IRIG-B
K: USB (Modbus RTU) + FO-LC (IEC 61850) + RJ45 (Modbus TCP or
DNP3.0 TCP) + IRIG-B
L: USB (Modbus RTU) + WiFi + FO-LC (IEC 61850) + RJ45 (Modbus
TCP or DNP3.0 TCP) + IRIG-B


FANOX SIL-A/ SIA-F 50/51/50N/51N 四相一體

FANOX Relay Series and Function Table

Attached: FANOX Protection functions summary.pdf

FANOX SIA-F / SIL-A  Feeder Protection 50/51/50N/51N


FANOX SIU-C UV+OV+81H+81L 六相一體/低頻電驛

FANOX SIU-C

27(2), 27V1, 59(2), 47, 59N(2), ΔV/ΔT, 74TCS, BF, 52, 79, 81O/U(4), 81R(2), 86, 78 and optionally 25.  DNP Modbus, TCP/IP 




FANOX RMU 用保護電驛 SIA Series

FANOX RMU 用保護電驛 SIA Series
SELF & DUAL POWERED (SELF+AUX)



Secondary Distribution. RMU SELF-POWERED Protection Relays – SIA RANGE

Overcurrent & Earth Fault Protection Relays. The most revolutionary solution for RMU’s (Ring Main Unit) protection. SIA relays are designed to protect the Secondary Transformers and Distribution Substations of Electrical Networks.


FANOX 6E/3E Motor/Pump 保護電驛

PBMB+PBMH
0b981242570c1fe4ad2ba3793abc172b.png

GL



EEx e Motor 


PUMP


FANOX 200kA SST 突波吸收器

FANOX 200kA SST 突波吸收器
f11831f2a9651626b69e481a2ae3b2c4.png62b75214c1dfb62cb2811d7c35a100aa.png