Overcurrent & Earth Fault Protection Relays. The most revolutionary solution for RMU’s (Ring Main Unit) protection. SIA relays are designed to protect the Secondary Transformers and Distribution Substations of Electrical Networks.
FANOX SIL-C 十相保護電驛
FUNCTIONS:
50 + SOTF + 50G + 50N + (4) 67/51 + (2) 67G/51G + (2) 67N/51N + 67GI
+ 67NI + 64REF + 46 + 46BC + 49 + 49T + 37 + (2) 27+ 27V1 + (2) 59 + (2)
59N/G + 47 + (4) 32 + (4) 81U/O + (4) 81R + 78 + (2) 24 + 79 + 74TCS +
60CTS + 60VTS + 50BF + SHB + CLP + 52 + 86 + HLT
COMMUNICATIONS:
A: USB (Modbus RTU) + RS485: (Modbus RTU, IEC60870-5-103 or DNP3.0
Serial)
B: USB (Modbus RTU) + RS485 (Modbus RTU, IEC60870-5-103 or DNP3.0
Serial) + RJ45 (Modbus TCP or DNP3.0 TCP or IEC60870-5-104)) + Web
Server + SNTP Protocol + IRIG-B
Attached: Feature comparison table - Fanox - Protection Relays.pdf
FANOX SIL-G 主盤/發電機保護電驛
Protection Functions :
50(2) + SOTF + 50G + 50N +67(4) + 67G(2) + 67N(2) + 46 + 46BC + 49 + 37 +27(2) + 27V1 + 59(2) +59N/G(2) + 47 + 32(4) + 81U/O(4) + 81R(4) + 78 + 24(2) + 79 + 74TCS+ 60CTS + 60VTS + 50BF + SHB + CLP + 52 + 86
COMMUNICATIONS
A: USB (Modbus RTU) + RS485: (Modbus RTU, IEC60870-5-103 or
DNP3.0 Serial)
B: USB (Modbus RTU) + RS485 (Modbus RTU, IEC60870-5-103 or
DNP3.0 Serial) + RJ45 (Modbus TCP or DNP3.0 TCP) + IRIG-B
C: USB (Modbus RTU) + Ethernet - RJ45 (IEC 61850) + RJ45 (Modbus
TCP or DNP3.0 TCP) + IRIG-B
D: USB (Modbus RTU) + HSR – FO (IEC 61850) + RJ45 (Modbus TCP
or DNP3.0 TCP) + IRIG-B
E: USB (Modbus RTU) + PRP – FO (IEC 61850) + RJ45 (Modbus TCP
or DNP3.0 TCP) + IRIG-B
F: USB (Modbus RTU) + WiFi + RS485 (Modbus RTU, IEC60870-5-
103 or DNP3.0 Serial)
G: USB (Modbus RTU) + WiFi + RS485 (Modbus RTU, IEC60870-5-
103 or DNP3.0 Serial) + RJ45 (Modbus TCP or DNP3.0 TCP) + IRIG-B
H: USB (Modbus RTU) + WiFi + Ethernet - RJ45 (IEC 61850) + RJ45
(Modbus TCP or DNP3.0 TCP) + IRIG-B
I: USB (Modbus RTU) + WiFi + HSR – FO (IEC 61850) + RJ45 (Modbus
TCP or DNP3.0 TCP) + IRIG-B
J: USB (Modbus RTU) + WiFi + PRP – FO (IEC61850) + RJ45 (Modbus
TCP or DNP3.0 TCP) + IRIG-B
K: USB (Modbus RTU) + FO-LC (IEC 61850) + RJ45 (Modbus TCP or
DNP3.0 TCP) + IRIG-B
L: USB (Modbus RTU) + WiFi + FO-LC (IEC 61850) + RJ45 (Modbus
TCP or DNP3.0 TCP) + IRIG-B
FANOX SIL-A/ SIA-F 50/51/50N/51N 四相一體

Attached: FANOX Protection functions summary.pdf
FANOX SIA-F / SIL-A Feeder Protection 50/51/50N/51N

FANOX SIU-C UV+OV+81H+81L 六相一體/低頻電驛
27(2), 27V1, 59(2), 47, 59N(2), ΔV/ΔT, 74TCS, BF, 52, 79, 81O/U(4), 81R(2), 86, 78 and optionally 25. DNP Modbus, TCP/IP

FANOX RMU 用保護電驛 SIA Series
SELF & DUAL POWERED (SELF+AUX)